EBSS Unlimited, LLC
SBA-Certified Service-Disabled Veteran-Owned Small BusinessTexas VetHUB
UEI RPKDGRRB6DC6CAGE 9P5Z3DeSoto, Texas

We build, maintain, and repair federal facilities that cannot close.

EBSS Unlimited is a service-disabled veteran-owned general contractor in DeSoto, Texas. We plan and manage construction, maintenance, inspection, and testing in VA medical centers and other occupied federal buildings across Arkansas, Colorado, Louisiana, Mississippi, Oklahoma, and Texas.

Owned and led by
Eric Bray
Eric Bray
Founder & President

Captain, U.S. Navy (Ret.). 27 years in Explosive Ordnance Disposal. Commanding Officer, Naval Ordnance Safety and Security Activity, the Navy's explosives-safety authority, 2019-2022. Legion of Merit, Bronze Star.

Wayne Boyter
Wayne Boyter
Co-Owner & Operations Manager

In construction since 1984, in management since 1993. Founded Acumen Enterprises, Inc. in 2001. Louisiana General Contractor No. 55926. USACE Construction Quality Management.

A principal answers for every job, from award through closeout.

Sample Past Performance

VA Amarillo Health Care System

$149,900
Contract 36C25725P09382025-2026

Replaced, installed, and tested coils on AHU-17 and AHU-2, Buildings 28 and 29, in an occupied VA medical center. Exceptional ratings on all CPARS elements.

VA North Texas HCS, Garland VA Medical Center

$54,984
Contract 36C25725P09192025

Emergency repair of air handler G-19 in an occupied VA medical center.

USDA Forest Service, San Juan National Forest

$264,000
Contract 1240LT25C00462025-2026

Emergency HVAC replacement at the Dolores Public Lands Office, Dolores, Colorado.

What we deliver

Construction

HVAC and mechanical

Air handlers and coils, chillers, boilers, piping, insulation, and controls, replaced in place.

ASHRAE 170, VA HVAC Design Manual, ASME B31.9

Electrical

Distribution, emergency generators, automatic transfer switches, and lighting.

NFPA 70, 70E, 99, and 110

Renovation and roofing

Interior work in occupied spaces, phased around operations. Roof repair and replacement.

ICRA, Interim Life Safety Measures, NFPA 101

Emergency repair and replacement

Mobilize, stabilize, replace. Two of our first projects began as responses to emergencies.

Construction management

Schedule, submittals, subcontracts, quality control, safety, and closeout, run by the owners.

USACE CQM, EM 385-1-1

Inspection, testing, and maintenance

Inspection

Elevators, medical gas systems, and fire suppression systems.

ASME A17.1, NFPA 99, NFPA 25

Water quality testing

Potable water and sterile processing water, sampled and analyzed.

VHA Directive 1061, AAMI ST108

Preventive maintenance

Transfer switches, generators, chillers, boilers, and roofs, on multi-year service contracts.

NFPA 110

Plant operations

Central plant operation and maintenance.

Sources sought and market research

Send to both principals: eric@ebss.me and wayne@ebss.me. Identifiers, codes, and bonding are in our capability statement, also a PDF.